Ningbo Jintian Copper (Group) Co., Ltd.
Ningbo Jintian Copper (Group) Co., Ltd.
Brass

C4430 Brass

Brass

Grade Name

C4430 Tin Brass (Naval Brass)


Key Features

  • Corrosion Resistance: Arsenic (0.02–0.06%) inhibits dezincification, ideal for marine environments.

  • Machinability: Excellent hot-working (760–800℃) and cold-forming capabilities.

  • Mechanical Properties: Tensile strength ≥315 MPa (annealed), elongation ≥15%.

  • Compliance: Meets GB/T 14954-1994 and ASTM B111M standards.


Product Forms & Dimensions

Form

Size Range

Standards

Rod

Diameter 2–300mm, Length 1–12m

JIS H3250-2015

Plate

Thickness 0.5–60mm, Width 100–2000mm

ASTM B36/B36M

Wire

Diameter 0.2–12mm, Coil ≥3kg

JIS H3300-2018

Tube

OD 5–300mm, Wall Thickness 0.5–30mm

EN 12449:1999

Strip

Thickness 0.1–2.5mm, Width ≤250mm

ASTM B134


Chemical Composition

Element

Content (%)

Standard Range

Cu

59.0–61.0

Main Component (GB/T 14954)

Sn

1.0–1.5

Corrosion Resistance

As

0.02–0.06

Dezincification Inhibitor

Fe

≤0.10

Impurity Control

Pb

≤0.30

Limited Content 1

Zn

Balance

Balancing Component

Impurities

≤1.0

Total Limit


Physical Properties

Property

Value/Description

Density

8.53 g/cm³

Electrical Conductivity

25% IACS (20℃)

Thermal Conductivity

64.0 W/(m·K)

Thermal Expansion

20×10⁻⁶/℃ (20–300℃)


Mechanical Properties


Condition

Tensile Strength (MPa)

Elongation (%)

Hardness (HRB)

Annealed (O)

315–379

≥15

50–65 HRB

Hard (H)

≥410

≥8

≥80 HB



Core Advantages

1. Marine Durability: Ideal for condensers and heat exchangers in seawater.

2. Versatile Processing: Adaptable to hot/cold working and welding.

3. Cost Efficiency: Balances strength and affordability for mass production.


Applications

  • Marine Engineering: Condenser tubes, ship fittings.

  • Energy Systems: Heat exchangers in power plants.

  • Architectural Hardware: Corrosion-resistant bolts and valves.

  • Electronics: Connectors and heat sinks (with protective coatings).


Processing Guidelines

  • Hot Working: 760–800℃, avoid 200–600℃ brittleness zone.

  • Annealing: 550–650℃ to relieve stress and restore ductility.

  • Post-Cold Working: Low-temperature annealing (200–300℃) to prevent stress corrosion.


FAQs

Q1: Differences between C4430 and C44300?

A: C44300 (ASTM) has higher Cu (69–71%) for extreme corrosion resistance, while C4430 focuses on cost-effectiveness.


Q2: Suitability for seawater?

A: Yes, but long-term exposure requires coatings and maintenance.


Standards

  • GB/T 14954-1994: Chinese tin brass standard1.

  • JIS H3300-2006: Japanese copper alloy tube standard8.

  • ASTM B111M: U.S. condenser and heat exchanger tube standard9


Start Your Partnership With JINTIAN COPPER!